1. 1 Technical description
smokehouse YX series allows to make automatically heat processing of butcher products such as drying, cooking , smoking and baking. without any additional operations
– It is possible to use cold smoke technology in a smoke chamber model equipped with chilling(opiton)
– it is made of stainless steel designated for usage in the food industry, the inner and outside sheet steel are made of sus304.
– the reinforced panels (thickness 80 mm) are insulated by the mineral wool.
– the whole construction of chambers, the used material included, provides their long life, perfect temperature insulation, operation reliability and energy savings
– the stainless steel floor with reinforcing against breaking through, antislide surface.
– the switch-board and the smoke generator are also manufactured of SUS 304 stainless steel and the standard position of them are on the left or the right side. In case of a special requirement, it is possible to place the switch-board outside the chamber (on a wall e.g.) and the smoke generator behind the chamber
– the air circulating system provides uniform air stream, temperature distribution and high-quality of drying, smoking and cooking in every place inside the chamber
– the chamber is equipped by two-speed fan, which provides the change of the air speed according to the program step, the fan is placed above the each smoking trolley
– the smoke chamber is equipped by a system of sensors, which measure temperature and relative humidity in the chamber. It is also supplied with the core temperature sensor and supports the “Delta-T“ method.
– the system of air-operated flaps control air input and output in the chamber and also the balance of pressure in the chamber and the surroundings
– the smoke chamber is fit with the system of automatic washing
Single row |
Double row |
Trolleys |
1 |
2 |
3 |
4 |
2×1 |
2×2 |
2×3 |
2×4 |
Capacity (kg/load) |
250 |
500 |
750 |
1000 |
500 |
1000 |
1500 |
2000 |
Power (kW) |
RYX |
4 |
8 |
12 |
16 |
8 |
16 |
24 |
32 |
RYXS |
5.5 |
10.2 |
14.2 |
20 |
10.2 |
20 |
28.4 |
40 |
Energy consumption |
(kW) |
30 |
60 |
90 |
120 |
60 |
120 |
180 |
240 |
Steam cost (kg/h) |
75 |
150 |
225 |
300 |
150 |
300 |
450 |
600 |
Gas/fuel cost (kW) |
30 |
60 |
90 |
120 |
60 |
120 |
180 |
|
RYX(mm) |
L |
1240 |
2350 |
3450 |
4550 |
1240 |
2350 |
3450 |
4550 |
W |
1460 |
1460 |
1460 |
1460 |
2850 |
2850 |
2850 |
2850 |
H |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
|
W1 |
990 |
990 |
990 |
990 |
990 |
990 |
990 |
990 |
RYXS(mm) |
L |
1400 |
2660 |
3760 |
4860 |
1400 |
2660 |
3760 |
4860 |
W |
1700 |
1700 |
1700 |
1700 |
3400 |
3400 |
3400 |
3400 |
H |
3085 |
3085 |
3085 |
3085 |
3085 |
3085 |
3085 |